back Open print view Show page as PDF

depiction:


DA31RF-15-150 Selbstst. Brandschutz-Unterdecke 1x15mm inkl. 150mm Mineralwolle

Ceiling, roof: ceiling within heated residential and office unit not subject to a U-value requirement (BG1) – IBO benchmarks 2020
login and edit copy of this building element
mass 16,0 kg/m²
PENRT 0 MJ/m²
GWP total 0 kg CO2/m²
AP 0 kg SO2/m²
no. type layer d
cm
λ
W/mK
R
m²K/W
ΔOI3
pts/m²
1 homogene Schichthomogene Schicht Rigips Feuerschutzplatte 1,50 0,250 0,06 ¹ 2
additional materials (thermally not relevant): (quantity per m² building element)
0,0028 kgRigips Glasfaserbewehrungsstreifen für Rigips Spachtelsysteme (Glass-fibre reinforcement)¹ 0
1,9 kgGlaswolledämmstoff "Isover" A1-A (ISOVER TW- KF Trennwandklemmfilz)¹ 7
0,015 kgRigips Drehstiftdübel 6/40 mm mit Schraubkopf (Polyamide (nylon))¹ 0
0,5 kgRigips Fugenfüller Vario¹ 0
0,029 kgRigips Schnellbauschraube TN 212 3,5 x 35 mm (Low-alloy steel (alloy content: 1 %))¹ 0
1,4 kgRigips RigiProfil C-Deckenprofil 0,6 mm 27/60/27, verzinktes Stahlblech ( (Steel sheet, galvanised)¹ 4
    building element 1,50   0

¹ layer is OI-relevant from BG2