back Open print view Show page as PDF

depiction:


1_UG_KF_AW_08 Außenwand STB 100 kg/m³ bei nicht drückendem Wasser (Perimeterdämmung)

Wall: outer wall (BG1) – IBO benchmarks 2020 project: Rsi=0.13; Rse=0;
login and edit copy of this building element
mass 588,2 kg/m²
PENRT 0 MJ/m²
GWP total 0 kg CO2/m²
AP 0 kg SO2/m²
no. type layer (from inside to outside) d
cm
λ
W/mK
R
m²K/W
ΔOI3
pts/m²
1 homogene Schichthomogene Schicht Reinforced concrete 100 kg/m³ reinforcing steel (1.25 vol. %) 25,00 2,300 0,11 ¹ 87
2 inhomogene Schichtinhomogene Schicht inhomogeneous (parts horizontal) 0,50      
    200 cm (67%) Vertical air layer, heat flow up d <= 6 mm 0,50 0,045 0,11 ¹ 0
    100 cm (33%) Mineral adhesive 0,50 1,000 0,01 ¹ 1
3 inhomogene Schichtinhomogene Schicht inhomogeneous (parts horizontal) 10,00      
    200 cm (67%) Vertical air layer, heat flow up 96 < d <= 100 mm 10,00 0,625 0,16 ¹ 0
    100 cm (33%) XPS–R 80 to 100 mm (32 kg/m³) 10,00 0,038 2,63 ¹ 6
4 inhomogene Schichtinhomogene Schicht inhomogeneous (parts horizontal) 0,50      
    200 cm (67%) Vertical air layer, heat flow up d <= 6 mm 0,50 0,045 0,11 ¹ 0
    100 cm (33%) ZementSockelputz ZP 62 0,50 0,830 0,01 ¹ 0
    building element 36,00   0

¹ layer is OI-relevant from BG3