back Open print view Show page as PDF

depiction:


copy (2) of EAm 04 a Brick outside wall in contact with ground

Wall: outer wall (BG1) – IBO benchmarks 2020
login and edit copy of this building element
mass 289,4 kg/m²
PENRT 0 MJ/m²
GWP total 0 kg CO2/m²
AP 0 kg SO2/m²
no. type layer (from inside to outside) d
cm
λ
W/mK
R
m²K/W
ΔOI3
pts/m²
1 homogene Schichthomogene Schicht CR lime cement finish plaster (1800 kg/m³) 1,50 1,050 0,01 ¹ 3
2 homogene Schichthomogene Schicht Vertically perforated brick 17 cm to 38 cm + normal mortar for brickwork (825 kg/m³) 30,00 0,270 1,11 ¹ 47
3 homogene Schichthomogene Schicht Bitumen coating 0,24 0,230 0,01 ¹ 7
4 homogene Schichthomogene Schicht Polymer bitumen sealing sheeting 0,78 0,230 0,03 ¹ 19
5 homogene Schichthomogene Schicht XPS–G 50 120 to 180 mm (38 kg/m³) 10,00 0,039 2,56 ¹ 22
    building element 42,52   0

¹ layer is OI-relevant from BG3