A++ A+ A B C D E F G
|
mass |
149,6 kg/m² |
PENRT |
1091 MJ/m² |
GWP total |
-62,9 kg CO2/m² |
AP |
0,255 kg SO2/m² |
|
no. |
type |
layer |
d cm |
λ W/mK |
R m²K/W |
ΔOI3 pts/m² |
1 |
|
Betondachsteine (Cement roofing tile / concrete roofing tile (2100 kg/m³)) |
2,61 |
¹ |
¹ |
² 9 |
2 |
|
inhomogeneous (parts normal to the eaves) |
3,00 |
|
|
|
|
|
57,5 cm (92%) Vertical air layer, heat flow up 26 < d <= 30 mm |
3,00 |
¹ |
¹ |
² 0 |
|
|
5 cm (8%) Timber (475 kg/m³ - e.g. spruce/fir) - rough, technically dried |
3,00 |
¹ |
¹ |
² 0 |
3 |
|
inhomogeneous (parts parallel to the eaves) |
5,00 |
|
|
|
|
|
57,5 cm (92%) Vertical air layer, horizontal heat flow 45 < d <= 50 mm |
5,00 |
¹ |
¹ |
² 0 |
|
|
5 cm (8%) Timber (475 kg/m³ - e.g. spruce/fir) - rough, technically dried |
5,00 |
¹ |
¹ |
² 0 |
4 |
|
Unterdeckplatte Holzfaser (Wood fibre WF-WD (250 kg/m³)) |
2,20 |
0,057 |
0,39 |
5 |
5 |
|
Holzfaserdämmplatte (GUTEX Thermosafe-homogen) |
24,00 |
0,043 |
5,58 |
22 |
6 |
|
Abdichtungsbahn (BauderTOP DIFUPLUS) |
0,06 |
0,500 |
0,00 |
² 3 |
7 |
|
Brettsperrholz BBS (5-lagig) (binderholz Brettsperrholz BBS (Fichte)) |
10,00 |
0,120 |
0,83 |
16 |
8 |
|
inhomogeneous (parts parallel to the eaves) |
6,00 |
|
|
|
|
|
56,5 cm (90%) ISOVER ULTIMATE UKF-034 twin Untersparren-Klemmfilz, vlieskaschiert |
6,00 |
0,034 |
1,76 |
5 |
|
|
6 cm (10%) Timber (475 kg/m³ - e.g. spruce/fir) - rough, air-dried |
6,00 |
0,120 |
0,50 |
0 |
9 |
|
Rigips Feuerschutzplatte |
1,25 |
0,250 |
0,05 |
2 |
|
|
Rsi / Rse = |
0,100 / 0,100 |
|
|
|
R' / R'' (max. relative error: 1,2%) = |
8,677 / 8,472 |
|
|
|
building element |
54,12 |
|
8,574 |
60 |
|