back Open print view Show page as PDF

depiction:


IW03c_

Wall: not bearing (BG1) – IBO benchmarks 2020
login and edit copy of this building element
mass 59,4 kg/m²
PENRT 0 MJ/m²
GWP total 0 kg CO2/m²
AP 0 kg SO2/m²
no. type layer (from inside to outside) d
cm
λ
W/mK
R
m²K/W
ΔOI3
pts/m²
1 homogene Schichthomogene Schicht Brettsperrholz BBS (5-lagig) (binderholz Brettsperrholz BBS (Fichte)) 10,00 0,120 0,83 ¹ 16
2 inhomogene Schicht mit 2 Subschichteninhomogene Schicht mit 2 Subschichten inhomogeneous (parts vertical) 7,00      
    56,5 cm (65%) ISOVER KONTUR KP 1- 035 5,00 0,034 1,47 ¹ 4
    56,5 cm (26%) Vertical air layer, heat flow up 16 < d <= 20 mm 2,00 0,133 0,15 ¹ 0
    6 cm (10%) Timber (475 kg/m³ - e.g. spruce/fir) - rough, technically dried 7,00 0,120 0,58 ¹ 0
3 homogene Schichthomogene Schicht Rigips Feuerschutzplatte 1,25 0,250 0,05 ¹ 2
    building element 18,25   0

¹ layer is OI-relevant from BG3