back Open print view Show page as PDF

depiction:


IW04d_

Wall: not bearing (BG1) – IBO benchmarks 2020
login and edit copy of this building element
mass 61,2 kg/mē
PENRT 0 MJ/mē
GWP total 0 kg CO2/mē
AP 0 kg SO2/mē
no. type layer (from inside to outside) d
cm
λ
W/mK
R
mēK/W
ΔOI3
pts/mē
1 homogene Schichthomogene Schicht Brettsperrholz BBS (5-lagig) (binderholz Brettsperrholz BBS (Fichte)) 10,00 0,120 0,83 ¹ 16
2 homogene Schichthomogene Schicht Luft (Vertical air layer, heat flow up 21 < d <= 25 mm) 2,50 0,167 0,15 ¹ 0
3 homogene Schichthomogene Schicht freistehende Vorsatzschale (Rigips Rigiprofil CW75) / Mineralwolle (z. B. Isover Kontur) (ISOVER KONTUR KP 1- 035) 6,00 0,034 1,76 ¹ 6
4 homogene Schichthomogene Schicht Rigips Feuerschutzplatte 1,25 0,250 0,05 ¹ 2
additional materials (thermally not relevant): (quantity per mē building element)
4,6 kgSteel sheet, galvanised¹ 14
    building element 19,75   0

¹ layer is OI-relevant from BG3