back Open print view Show page as PDF

depiction:


IW18_

Wall: Partition wall between residential or office units (BG1) – IBO benchmarks 2020
login and edit copy of this building element
0,277 W/mēK
A++
A+
A
B
C
D
E
F
G
OI-Class (BG1)³
A++
mass 117,1 kg/mē
PENRT 0 MJ/mē
GWP total 0 kg CO2/mē
AP 0 kg SO2/mē
no. type layer (from inside to outside) d
cm
λ
W/mK
R
mēK/W
ΔOI3
pts/mē
1 homogene Schichthomogene Schicht Rigips Feuerschutzplatte 1,25 0,250 0,05 ¹ 2
2 homogene Schichthomogene Schicht Brettsperrholz BBS (3-lagig) (binderholz Brettsperrholz BBS (Fichte)) 9,00 0,120 0,75 ¹ 14
3 homogene Schichthomogene Schicht Rigips Feuerschutzplatte 1,25 0,250 0,05 ¹ 2
4 homogene Schichthomogene Schicht ISOVER KONTUR KP 1- 035 5,00 0,034 1,47 ¹ 5
5 homogene Schichthomogene Schicht Luftschicht (Vertical air layer, heat flow up 6 < d <= 10 mm) 1,00 0,071 0,14 ¹ 0
6 homogene Schichthomogene Schicht Brettsperrholz BBS (5-lagig) (binderholz Brettsperrholz BBS (Fichte)) 10,00 0,120 0,83 ¹ 16
7 homogene Schichthomogene Schicht Rigips Feuerschutzplatte 1,25 0,250 0,05 ¹ 2
    Rsi / Rse = 0,130 / 0,130  
    R' / R'' (max. relative error: 0,0%) = 3,605 / 3,605  
    building element 28,75   3,605 0

¹ layer is OI-relevant from BG3
² U value (Heat transfer coefficient) calculated according to ÖNORM EN ISO 6946.
³ For the OI class, the U-value of the component is taken into account in addition to the ecological key figures