A++ A+ A B C D E F G
|
mass |
84,6 kg/m² |
PENRT |
806 MJ/m² |
GWP total |
-32,4 kg CO2/m² |
AP |
0,332 kg SO2/m² |
|
no. |
type |
layer (from inside to outside) |
d cm |
λ W/mK |
R m²K/W |
ΔOI3 pts/m² |
1 |
|
Rigips Feuerschutzplatte (Rigips Feuerschutzplatte) |
1,25 |
0,250 |
0,05 |
2 |
2 |
|
inhomogeneous (parts vertical) |
7,00 |
|
|
|
|
|
56,5 cm (65%) ISOVER KONTUR KP 1- 035 |
5,00 |
0,034 |
1,47 |
4 |
|
|
56,5 cm (26%) Vertical air layer, heat flow up 16 < d <= 20 mm |
2,00 |
0,133 |
0,15 |
0 |
|
|
6 cm (10%) Timber (475 kg/m³ - e.g. spruce/fir) - rough, technically dried |
7,00 |
0,120 |
0,58 |
0 |
3 |
|
Brettsperrholz BBS (3-lagig) (binderholz Brettsperrholz BBS (Fichte)) |
9,00 |
0,120 |
0,75 |
14 |
4 |
|
Mineralwolle vollflächig (ISOVER INTEGRA AP BASIC AUFSPARRENDÄMMPLATTE) |
16,00 |
0,035 |
4,57 |
45 |
5 |
|
Unterspannbahn (Polyethylene (PE) sealing sheeting) |
0,02 |
0,500 |
0,00 |
¹ 1 |
6 |
|
inhomogeneous (parts vertical) |
4,00 |
|
|
|
|
|
56,5 cm (90%) Vertical air layer, heat flow up 36 < d <= 40 mm |
4,00 |
² |
² |
¹ 0 |
|
|
6 cm (10%) Timber (475 kg/m³ - e.g. spruce/fir) - rough, technically dried |
4,00 |
² |
² |
¹ 0 |
7 |
|
Holz Außenwandverkleidung, plattenförmig ohne Fugen (Timber (525 kg/m³ - e.g. larch) - rough, technically dried) |
1,90 |
² |
² |
¹ 0 |
|
|
Rsi / Rse = |
0,130 / 0,130 |
|
|
|
R' / R'' (max. relative error: 1,2%) = |
7,138 / 6,967 |
|
|
|
building element |
39,17 |
|
7,053 |
66 |
|