back Open print view Show page as PDF

depiction:


2_IW_wtr_001 Massiv wohnungstrennend (20 cm, beidseitig CW 50)

Wall: bearing (BG1) – IBO benchmarks 2020 project: Rsi=0.13; Rse=0.13;
login and edit copy of this building element
mass 506,2 kg/m²
PENRT 0 MJ/m²
GWP total 0 kg CO2/m²
AP 0 kg SO2/m²
no. type layer (from inside to outside) d
cm
λ
W/mK
R
m²K/W
ΔOI3
pts/m²
1 homogene Schichthomogene Schicht Gypsum plasterboard (700 kg/m³) 1,25 0,210 0,06 ¹ 2
2 homogene Schichthomogene Schicht Gypsum plasterboard (700 kg/m³) 1,25 0,210 0,06 ¹ 2
3 homogene Schichthomogene Schicht Glass wool MW(GW)-W (24 kg/m³) 5,00 0,036 1,39 ² 5
4 homogene Schichthomogene Schicht Stahlbeton 100 kg/m³ Armierungsstahl (1,25 Vol.%) (Reinforced concrete 100 kg/m³ reinforcing steel (1.25 vol. %)) 20,00 2,300 0,09 ² 69
5 homogene Schichthomogene Schicht Glass wool MW(GW)-W (24 kg/m³) 5,00 0,036 1,39 ² 5
6 homogene Schichthomogene Schicht Gypsum plasterboard (700 kg/m³) 1,25 0,210 0,06 ² 2
7 homogene Schichthomogene Schicht Gypsum plasterboard (700 kg/m³) 1,25 0,210 0,06 ² 2
additional materials (thermally not relevant): (quantity per m² building element)
3,8 kgCW Profil 50 (unten+oben+vertikal (Steel sheet, galvanised)¹ 12
    building element 35,00   0

¹ layer is OI-relevant from BG3
² layer is OI-relevant from BG2