back Open print view Show page as PDF

depiction:


2_IW_wtr_004 Massiv wohnungstrennend (25 cm, einseitig CW 50 + Installationebene)

Wall: bearing (BG1) – IBO benchmarks 2020
login and edit copy of this building element
mass 603,8 kg/m²
PENRT 0 MJ/m²
GWP total 0 kg CO2/m²
AP 0 kg SO2/m²
no. type layer (from inside to outside) d
cm
λ
W/mK
R
m²K/W
ΔOI3
pts/m²
1 homogene Schichthomogene Schicht Reinforced concrete 100 kg/m³ reinforcing steel (1.25 vol. %) 25,00 ¹ ¹ ² 87
2 homogene Schichthomogene Schicht Glass wool MW(GW)-W (24 kg/m³) 5,00 ¹ ¹ ² 5
3 homogene Schichthomogene Schicht Installationsebene ungedämmt (Vertical air layer, horizontal heat flow 45 < d <= 50 mm) 5,00 ¹ ¹ ² 0
4 homogene Schichthomogene Schicht Gypsum plasterboard (700 kg/m³) 1,25 0,210 0,06 ³ 2
5 homogene Schichthomogene Schicht Gypsum plasterboard (700 kg/m³) 1,25 0,210 0,06 ³ 2
additional materials (thermally not relevant): (quantity per m² building element)
3,8 kgC-Profil (2 x 50er Profile) (Steel sheet, galvanised)² 12
    building element 37,50   0

¹ not relevant
² layer is OI-relevant from BG3
³ layer is OI-relevant from BG2