A++ A+ A B C D E F G
|
mass |
105,4 kg/m² |
PENRT |
455 MJ/m² |
GWP total |
-144 kg CO2/m² |
AP |
0,170 kg SO2/m² |
|
no. |
type |
layer (from inside to outside) |
d cm |
λ W/mK |
R m²K/W |
ΔOI3 pts/m² |
1 |
|
Brettstapelwand verdübelt (Timber (475 kg/m³ - e.g. spruce/fir) - planed, technically dried) |
12,00 |
0,120 |
1,00 |
3 |
2 |
|
Dampfbremse PE (Polyethylene (PE) sealing sheeting) |
0,02 |
0,500 |
0,00 |
¹ 1 |
3 |
|
inhomogeneous (parts vertical) |
4,00 |
|
|
|
|
|
58,5 cm (94%) Cellulose vertical cavity wall insulation (54 kg/m³) |
4,00 |
0,041 |
0,98 |
1 |
|
|
4 cm (6%) Timber (475 kg/m³ - e.g. spruce/fir) - rough, technically dried |
4,00 |
0,120 |
0,33 |
0 |
4 |
|
inhomogeneous (parts vertical) |
22,00 |
|
|
|
|
|
61,1 cm (98%) Cellulose vertical cavity wall insulation (54 kg/m³) |
22,00 |
0,041 |
5,37 |
6 |
|
|
1,4 cm (2%) OSB boards (650 kg/m³) |
22,00 |
0,130 |
1,69 |
1 |
5 |
|
inhomogeneous (parts vertical) |
4,00 |
|
|
|
|
|
58,5 cm (94%) Cellulose vertical cavity wall insulation (54 kg/m³) |
4,00 |
0,041 |
0,98 |
1 |
|
|
4 cm (6%) Timber (475 kg/m³ - e.g. spruce/fir) - rough, technically dried |
4,00 |
0,120 |
0,33 |
0 |
6 |
|
PE-Folie diffusionsoffen (Polyethylene (PE) sealing sheeting) |
0,01 |
0,500 |
0,00 |
¹ 0 |
7 |
|
Timber (475 kg/m³ - e.g. spruce/fir) - rough, technically dried |
2,40 |
0,120 |
0,20 |
0 |
8 |
|
inhomogeneous (parts vertical) |
5,00 |
|
|
|
|
|
72 cm (90%) Vertical air layer, horizontal heat flow 45 < d <= 50 mm |
5,00 |
² |
² |
¹ 0 |
|
|
8 cm (10%) Timber (475 kg/m³ - e.g. spruce/fir) - rough, technically dried |
5,00 |
² |
² |
¹ 0 |
9 |
|
Timber (525 kg/m³ - e.g. larch) - planed, technically dried |
2,50 |
² |
² |
¹ 1 |
|
|
Rsi / Rse = |
0,130 / 0,130 |
|
|
|
R' / R'' (max. relative error: 0,9%) = |
8,476 / 8,321 |
|
|
|
building element |
51,93 |
|
8,398 |
14 |
|