back Open print view Show page as PDF

depiction:


AWm 06 b Heavy honeycomb brick outside wall, special ETICS

Wall: exposed to outside air – not back-ventilated (BG1) – IBO benchmarks 2012
login and edit copy of this building element
0,128 W/m²K
A++
A+
A
B
C
D
E
F
G
OI-Class (BG1)²
A
mass 343,9 kg/m²
PENRT 981 MJ/m²
GWP total -11,3 kg CO2/m²
AP 0,245 kg SO2/m²
no. type layer (from inside to outside) d
cm
λ
W/mK
R
m²K/W
ΔOI3
pts/m²
1 homogene Schichthomogene Schicht Clay plaster 1,50 0,810 0,02 1
2 homogene Schichthomogene Schicht Vertically perforated brick 17 cm to 38 cm + normal mortar for brickwork (1250 kg/m³) 20,00 0,470 0,43 44
3 homogene Schichthomogene Schicht Mineral adhesive 0,50 1,000 0,01 3
4 homogene Schichthomogene Schicht Insulation cork (140 kg/m³) 36,00 0,050 7,20 13
5 homogene Schichthomogene Schicht Silicate plaster (without synthetic resin additive) 0,50 0,800 0,01 3
    Rsi / Rse = 0,130 / 0,040  
    R' / R'' (max. relative error: 0,0%) = 7,825 / 7,825  
    building element 58,50   7,825 63

¹ U value (Heat transfer coefficient) calculated according to ÖNORM EN ISO 6946.
² For the OI class, the U-value of the component is taken into account in addition to the ecological key figures