A++ A+ A B C D E F G
|
mass |
483,7 kg/m² |
PENRT |
1789 MJ/m² |
GWP total |
95,3 kg CO2/m² |
AP |
0,254 kg SO2/m² |
|
no. |
type |
layer (from inside to outside) |
d cm |
λ W/mK |
R m²K/W |
ΔOI3 pts/m² |
1 |
|
Clay plaster |
1,50 |
0,810 |
0,02 |
1 |
2 |
|
Vertically perforated brick 17 cm to 38 cm + light masonry mortar (775 kg/m³) |
25,00 |
0,250 |
1,00 |
34 |
3 |
|
Hanfdämmplatte (Hemp fibre insulation (41 kg/m³)) |
20,00 |
0,045 |
4,44 |
13 |
4 |
|
Hanfdämmplatte (Hemp fibre insulation (41 kg/m³)) |
10,00 |
0,045 |
2,22 |
7 |
5 |
|
Windsperre PE, diffusionsoffen (Polyethylene (PE) roof underlay - open to diffusion) |
0,01 |
0,500 |
0,00 |
¹ 0 |
6 |
|
Vertical air layer, horizontal heat flow 35 < d <= 40 mm |
4,00 |
² |
² |
¹ 0 |
7 |
|
Full clinker + normal mortar for brickwork (2100 kg/m³) |
12,00 |
² |
² |
¹ 55 |
|
|
Rsi / Rse = |
0,130 / 0,130 |
|
|
|
R' / R'' (max. relative error: 0,0%) = |
7,945 / 7,945 |
|
|
|
building element |
72,51 |
|
7,945 |
109 |
|