back Open print view Show page as PDF

depiction:


Efo 01 a Slab foundation, insulated upper side, wet screed

Floor: in contact with ground – heat flow descending (BG1) – IBO benchmarks 2012
login and edit copy of this building element
0,159 W/m²K
A++
A+
A
B
C
D
E
F
G
OI-Class (BG1)4
C
mass 738,1 kg/m²
PENRT 1722 MJ/m²
GWP total 104 kg CO2/m²
AP 0,368 kg SO2/m²
no. type layer d
cm
λ
W/mK
R
m²K/W
ΔOI3
pts/m²
1 homogene Schichthomogene Schicht Multi-layer parquet 1,20 0,160 0,08 ¹ 12
2 homogene Schichthomogene Schicht Adhesive - artificial resin 0,10 0,900 0,00 ¹ 2
3 homogene Schichthomogene Schicht Cement and cement flowing screed (2000 kg/m³) 5,00 1,330 0,04 9
4 homogene Schichthomogene Schicht Polyethylene foam (70 kg/m³) 1,00 0,050 0,20 3
5 homogene Schichthomogene Schicht XPS–G 30 > 180 mm (32 kg/m³) 24,00 0,042 5,71 45
6 homogene Schichthomogene Schicht Aluminium bitumen sealing membrane 0,40 0,230 0,02 ¹ 14
7 homogene Schichthomogene Schicht Normal concrete with reinforcement 1 % (2300 kg/m³) 15,00 2,300 0,07 34
8 homogene Schichthomogene Schicht Building paper 0,03 ² ² ¹ 0
9 homogene Schichthomogene Schicht Fillings made of sand, gravel, grit (1800 kg/m³) 15,00 ² ² ¹ 3
10 homogene Schichthomogene Schicht PP fleece 0,02 ² ² ¹ 0
    Rsi / Rse = 0,170 / 0,000  
    R' / R'' (max. relative error: 0,0%) = 6,281 / 6,281  
    building element 61,75   6,281 124

¹ layer is OI-relevant from BG1
² not relevant
³ U value (Heat transfer coefficient) calculated according to ÖNORM EN ISO 6946.
4 For the OI class, the U-value of the component is taken into account in addition to the ecological key figures