back Open print view Show page as PDF

depiction:


Efu 03 a Slab foundation, insulated lower side, wood floor on raft batten

Floor: in contact with ground – heat flow descending (BG1) – IBO benchmarks 2012
login and edit copy of this building element
0,147 W/m²K
A++
A+
A
B
C
D
E
F
G
OI-Class (BG1)4
E
mass 895,9 kg/m²
PENRT 2443 MJ/m²
GWP total 115 kg CO2/m²
AP 0,550 kg SO2/m²
no. type layer d
cm
λ
W/mK
R
m²K/W
ΔOI3
pts/m²
1 homogene Schichthomogene Schicht Multi-layer parquet 1,20 0,160 0,08 ¹ 12
2 homogene Schichthomogene Schicht Adhesive - artificial resin 0,10 0,900 0,00 ¹ 2
3 homogene Schichthomogene Schicht Internal chipboard (650 kg/m³) 2,20 0,130 0,17 4
4 inhomogene Schichtinhomogene Schicht inhomogeneous (parts transverse) 5,00      
    49,8 cm (80%) Glass wool MW(GW)-W (18 kg/m³) 5,00 0,038 1,32 3
    12,8 cm (20%) Timber (475 kg/m³ - e.g. spruce/fir) - rough, technically dried 5,00 0,120 0,42 0
5 homogene Schichthomogene Schicht Glass wool MW(GW)-T (80 kg/m³) 1,50 0,035 0,43 5
6 homogene Schichthomogene Schicht Polyethylene (PE) sealing sheeting 0,02 ² ² ¹ 1
7 homogene Schichthomogene Schicht Normal concrete with reinforcement 1 % (2300 kg/m³) 20,00 2,300 0,09 46
8 homogene Schichthomogene Schicht Polyethylene (PE) sealing sheeting 0,04 ² ² ¹ 1
9 homogene Schichthomogene Schicht Schaumglasplatten (Foamglas T4+) 20,00 0,041 4,88 68
10 homogene Schichthomogene Schicht Polymer bitumen sealing sheeting 1,00 ² ² ¹ 25
11 homogene Schichthomogene Schicht Lean concrete / cast and compressed concrete 5,00 ² ² ¹ 4
12 homogene Schichthomogene Schicht Building paper 0,03 ² ² ¹ 0
13 homogene Schichthomogene Schicht Fillings made of sand, gravel, grit (1800 kg/m³) 15,00 ² ² ¹ 3
14 homogene Schichthomogene Schicht PP fleece 0,02 ² ² ¹ 0
    Rsi / Rse = 0,170 / 0,000  
    R' / R'' (max. relative error: 1,5%) = 6,921 / 6,723  
    building element 71,11   6,822 174

¹ layer is OI-relevant from BG1
² not relevant
³ U value (Heat transfer coefficient) calculated according to ÖNORM EN ISO 6946.
4 For the OI class, the U-value of the component is taken into account in addition to the ecological key figures