KDo 02 b Basement ceiling slab, insulated upper side, spacer floor

Floor: exposed to unheated parts of buildings – heat flow descending (BG1) – IBO benchmarks 2012
login and edit copy of this building element
0,153 W/m²K
A++
A+
A
B
C
D
E
F
G
OI-Class (BG1)4
A++
mass 277,5 kg/m²
PENRT 608 MJ/m²
GWP total 1,48 kg CO2/m²
AP 0,152 kg SO2/m²
no. type layer d
cm
λ
W/mK
R
m²K/W
ΔOI3
pts/m²
1 homogene Schichthomogene Schicht Multi-layer parquet 1,20 0,160 0,08 ¹ 12
2 homogene Schichthomogene Schicht Polyethylene foam (70 kg/m³) 0,50 0,050 0,10 2
3 homogene Schichthomogene Schicht Dampfbremse PE (Polyethylene (PE) sealing sheeting) 0,02 0,500 0,00 ¹ 1
4 homogene Schichthomogene Schicht Internal chipboard (650 kg/m³) 3,20 0,130 0,25 6
5 homogene Schichthomogene Schicht Schafwolle (Isolena Schafwolle, Optimal, 18 kg/m³) 12,00 0,043 2,79 3
6 homogene Schichthomogene Schicht Schafwolle (Isolena Schafwolle, Optimal, 18 kg/m³) 12,00 0,043 2,79 3
7 homogene Schichthomogene Schicht Concrete concave ceiling (1200 kg/m³) 20,00 1,000 0,20 15
additional materials (thermally not relevant): (quantity per m² building element)
3,0 kgDistanzbodenhalter (Steel sheet, galvanised)² 8
    Rsi / Rse = 0,170 / 0,170  
    R' / R'' (max. relative error: 0,0%) = 6,543 / 6,543  
    building element 48,92   6,543 41

¹ layer is OI-relevant from BG1
² layer is OI-relevant from BG3
³ U value (Heat transfer coefficient) calculated according to ÖNORM EN ISO 6946.