Abbildung: Decke gegen unbeh. Keller

Floor: exposed to unheated parts of buildings – heat flow descending (BG1) – IBO benchmarks 2012 project: Beispiel client: EIV
login and edit copy of this building element
A++
RL6
0,182 W/m²K
A++
A+
A
B
C
D
E
F
G
OI-Class (BG1)³
C
mass 624,9 kg/m²
PENRT 1681 MJ/m²
GWP total 104 kg CO2/m²
AP 0,410 kg SO2/m²
no. type layer d
cm
λ
W/mK
R
m²K/W
ΔOI3
pts/m²
1 homogene Schichthomogene Schicht Solid parquet 1,30 0,160 0,08 ¹ 12
2 homogene Schichthomogene Schicht Calcium sulphate screed and floor sreed (1800 kg/m³) 7,00 0,930 0,08 13
3 homogene Schichthomogene Schicht XPS–G 50 120 to 180 mm (38 kg/m³) 14,00 0,039 3,59 31
4 homogene Schichthomogene Schicht Polyethylene (PE) vapour brake 0,01 0,500 0,00 ¹ 0
5 homogene Schichthomogene Schicht Reinforced concrete 100 kg/m³ reinforcing steel (1.25 vol. %) 20,00 2,300 0,09 52
6 inhomogene Schichtinhomogene Schicht inhomogeneous (parts along) 5,00      
    58,5 cm (94%) Glass wool MW(GW)-WV (70 kg/m³) 5,00 0,035 1,43 13
    4 cm (6%) Timber (475 kg/m³ - e.g. spruce/fir) - rough, technically dried 5,00 0,120 0,42 0
7 homogene Schichthomogene Schicht Gypsum fibreboard (1125 kg/m³) 1,25 0,400 0,03 6
    Rsi / Rse = 0,170 / 0,170  
    R' / R'' (max. relative error: 1,0%) = 5,555 / 5,441  
    building element 48,56   5,498 128

¹ layer is OI-relevant from BG1
² U value (Heat transfer coefficient) calculated according to ÖNORM EN ISO 6946. A++: U-Werte im Bereich der Markierung A++ (0,20 W/m²K) sind notwendig, um derartige Gebäude zu errichten. RL6: OIB Richtlinie 6 (April 2007); In ganz Österreich seit 1.1.08 verbindlich festgelegter max. U-Wert (0,40 W/m²K) für alle Neubauten sowie instandgesetzte bzw. erneuerte Bauteile.
³ For the OI class, the U-value of the component is taken into account in addition to the ecological key figures