back Open print view Show page as PDF

depiction:


De 03a: Kellerdecke saniert, Stahlbeton (Steinwolle)

Floor: exposed to outside air – not back-ventilated – heat flow descending (BG1) – IBO benchmarks 2012 project: Althaussanierung - Messemodell client: EIV
login and edit copy of this building element
A++
RL6
0,176 W/m²K
A++
A+
A
B
C
D
E
F
G
OI-Class (BG1)³
D
mass 660,4 kg/m²
PENRT 1591 MJ/m²
GWP total 127 kg CO2/m²
AP 0,573 kg SO2/m²
no. type layer d
cm
λ
W/mK
R
m²K/W
ΔOI3
pts/m²
1 homogene Schichthomogene Schicht Solid parquet 2,00 0,160 0,13 ¹ 19
2 homogene Schichthomogene Schicht Cement and cement flowing screed (1800 kg/m³) 7,00 1,100 0,06 12
3 homogene Schichthomogene Schicht Trittschalldämmung (Glass wool MW(GW)-T (80 kg/m³)) 3,50 0,035 1,00 11
4 homogene Schichthomogene Schicht Reinforced concrete 100 kg/m³ reinforcing steel (1.25 vol. %) 20,00 2,300 0,09 52
5 homogene Schichthomogene Schicht Mineral adhesive 0,50 1,000 0,01 3
6 homogene Schichthomogene Schicht Rock wool MW(SW)-PT 5 (105 kg/m³) 16,00 0,038 4,21 49
7 homogene Schichthomogene Schicht Innenputz (Gypsum plaster (1300 kg/m³)) 2,00 0,570 0,04 5
    Rsi / Rse = 0,130 / 0,040  
    R' / R'' (max. relative error: 0,0%) = 5,696 / 5,696  
    building element 51,00   5,696 151

¹ layer is OI-relevant from BG1
² U value (Heat transfer coefficient) calculated according to ÖNORM EN ISO 6946. A++: U-Werte im Bereich der Markierung A++ (0,14 W/m²K) sind notwendig, um derartige Gebäude zu errichten. RL6: OIB Richtlinie 6 (April 2007); In ganz Österreich seit 1.1.08 verbindlich festgelegter max. U-Wert (0,20 W/m²K) für alle Neubauten sowie instandgesetzte bzw. erneuerte Bauteile.
³ For the OI class, the U-value of the component is taken into account in addition to the ecological key figures