SD 02: Steildach hinterlüftet

Ceiling, roof, 25°: Flat or pitched roof exposed to outside air – back-ventilated – heat flow ascending (BG1) – IBO benchmarks 2012 project: Althaussanierung - Bestand client: Energieinstitut
login and edit copy of this building element
A++
RL6
2,515 W/m²K
A++
A+
A
B
C
D
E
F
G
OI-Class (BG1)4
G
mass 72,3 kg/m²
PENRT 348 MJ/m²
GWP total -30,4 kg CO2/m²
AP 0,0903 kg SO2/m²
no. type layer d
cm
λ
W/mK
R
m²K/W
ΔOI3
pts/m²
1 homogene Schichthomogene Schicht Clay roof tiles (2000 kg/m³) 2,00 ¹ ¹ ² 11
2 inhomogene Schichtinhomogene Schicht inhomogeneous (parts parallel to the eaves) 3,00      
    26 cm (87%) Vertical air layer, heat flow up 26 < d <= 30 mm 3,00 ¹ ¹ ² 0
    4 cm (13%) Timber (475 kg/m³ - e.g. spruce/fir) - rough, air-dried 3,00 ¹ ¹ ² 0
3 inhomogene Schichtinhomogene Schicht inhomogeneous (parts normal to the eaves) 5,00      
    75 cm (94%) Vertical air layer, heat flow up 46 < d <= 50 mm 5,00 ¹ ¹ ² 0
    5 cm (6%) Timber (475 kg/m³ - e.g. spruce/fir) - rough, technically dried 5,00 ¹ ¹ ² 0
4 homogene Schichthomogene Schicht Unterdachplatte (Plywood and veneer timber for interior use (600 kg/m³)) 2,00 0,120 0,17 9
5 inhomogene Schichtinhomogene Schicht inhomogeneous (parts normal to the eaves) 20,00      
    56,5 cm (82%) Vertical air layer, heat flow up 196 < d <= 200 mm 20,00 ¹ ¹ ² 0
    12 cm (18%) Timber (475 kg/m³ - e.g. spruce/fir) - rough, air-dried 20,00 0,120 1,67 -2
    Rsi / Rse = 0,100 / 0,100  
    R' / R'' (max. relative error: 7,8%) = 0,429 / 0,367  
    building element 32,00   0,398 19

¹ not relevant
² layer is OI-relevant from BG1
³ U value (Heat transfer coefficient) calculated according to ÖNORM EN ISO 6946. A++: U-Werte im Bereich der Markierung A++ (0,12 W/m²K) sind notwendig, um derartige Gebäude zu errichten. RL6: OIB Richtlinie 6 (April 2007); In ganz Österreich seit 1.1.08 verbindlich festgelegter max. U-Wert (0,20 W/m²K) für alle Neubauten sowie instandgesetzte bzw. erneuerte Bauteile.