AW 01a: Betonhohlsteinmauer saniert (EPS)

Wall: exposed to outside air – not back-ventilated (BG1) – IBO benchmarks 2012 project: Althaussanierung - Messemodelle client: EIV
login and edit copy of this building element
A++
RL6
0,172 W/m²K
A++
A+
A
B
C
D
E
F
G
OI-Class (BG1)²
B
mass 518,2 kg/m²
PENRT 903 MJ/m²
GWP total 71,6 kg CO2/m²
AP 0,204 kg SO2/m²
no. type layer (from inside to outside) d
cm
λ
W/mK
R
m²K/W
ΔOI3
pts/m²
1 homogene Schichthomogene Schicht Normal plastering mortar GP lime cement (1800 kg/m³) 1,50 1,050 0,01 3
2 homogene Schichthomogene Schicht Wood wool panel WW, magnesite-bonded (350 kg/m³) 4,00 0,110 0,36 3
3 homogene Schichthomogene Schicht Mineral adhesive 0,50 1,000 0,01 3
4 homogene Schichthomogene Schicht Hollow concrete blocks (1400 kg/m³) 30,00 1,200 0,25 26
5 homogene Schichthomogene Schicht One-layer plastering mortar for external OC lime cement mortar (1800 kg/m³) 1,50 1,050 0,01 3
6 homogene Schichthomogene Schicht Mineral adhesive 0,50 1,000 0,01 3
7 homogene Schichthomogene Schicht EPS-F (15.8 kg/m³) 20,00 0,040 5,00 19
8 homogene Schichthomogene Schicht Silicate plaster with synthetic resin additive, reinforced 0,50 0,800 0,01 9
    Rsi / Rse = 0,130 / 0,040  
    R' / R'' (max. relative error: 0,0%) = 5,828 / 5,828  
    building element 58,50   5,828 69

¹ U value (Heat transfer coefficient) calculated according to ÖNORM EN ISO 6946. A++: U-Werte im Bereich der Markierung A++ (0,13 W/m²K) sind notwendig, um derartige Gebäude zu errichten. RL6: OIB Richtlinie 6 (April 2007); In ganz Österreich seit 1.1.08 verbindlich festgelegter max. U-Wert (0,35 W/m²K) für alle Neubauten sowie instandgesetzte bzw. erneuerte Bauteile.