depiction:


AW 08: Holzblockwand

Wall: exposed to outside air – back-ventilated (BG1) – IBO benchmarks 2012 project: Althaussanierung - Messemodell client: EIV
login and edit copy of this building element
A++
RL6
0,467 W/m²K
A++
A+
A
B
C
D
E
F
G
OI-Class (BG1)²
A++
mass 115,9 kg/m²
PENRT 328 MJ/m²
GWP total -189 kg CO2/m²
AP 0,122 kg SO2/m²
no. type layer (from inside to outside) d
cm
λ
W/mK
R
m²K/W
ΔOI3
pts/m²
1 homogene Schichthomogene Schicht Holztäfer (Timber (475 kg/m³ - e.g. spruce/fir) - planed, technically dried) 2,00 0,120 0,17 0
2 inhomogene Schichtinhomogene Schicht inhomogeneous (parts horizontal) 3,00      
    56,5 cm (90%) Vertical air layer, horizontal heat flow 25 < d <= 30 mm 3,00 0,176 0,17 0
    6 cm (10%) Timber (475 kg/m³ - e.g. spruce/fir) - rough, technically dried 3,00 0,120 0,25 0
3 homogene Schichthomogene Schicht Holzblockwand (Timber (525 kg/m³ - e.g. larch) - rough, technically dried) 20,00 0,130 1,54 -5
    Rsi / Rse = 0,130 / 0,130  
    R' / R'' (max. relative error: 0,0%) = 2,143 / 2,141  
    building element 25,00   2,142 -4

¹ U value (Heat transfer coefficient) calculated according to ÖNORM EN ISO 6946. A++: U-Werte im Bereich der Markierung A++ (0,13 W/m²K) sind notwendig, um derartige Gebäude zu errichten. RL6: OIB Richtlinie 6 (April 2007); In ganz Österreich seit 1.1.08 verbindlich festgelegter max. U-Wert (0,35 W/m²K) für alle Neubauten sowie instandgesetzte bzw. erneuerte Bauteile.
² For the OI class, the U-value of the component is taken into account in addition to the ecological key figures