A++ A+ A B C D E F G
|
mass |
97,4 kg/m² |
PENRT |
128 MJ/m² |
GWP total |
-50,7 kg CO2/m² |
AP |
0,0475 kg SO2/m² |
|
no. |
type |
layer |
d cm |
λ W/mK |
R m²K/W |
ΔOI3 pts/m² |
1 |
|
Timber (475 kg/m³ - e.g. spruce/fir) - planed, technically dried |
2,50 |
0,120 |
0,21 |
¹ 1 |
2 |
|
inhomogeneous (parts along) |
3,00 |
|
|
|
|
|
62,5 cm (95%) Vertical air layer, horizontal heat flow 25 < d <= 30 mm |
3,00 |
² |
² |
¹ 0 |
|
|
3 cm (5%) Timber (475 kg/m³ - e.g. spruce/fir) - rough, technically dried |
3,00 |
0,120 |
0,25 |
0 |
3 |
|
Building paper |
0,03 |
0,170 |
0,00 |
¹ 0 |
4 |
|
inhomogeneous (parts transverse) |
16,00 |
|
|
|
|
|
62,5 cm (17%) Vertical air layer, heat flow up 31 < d <= 35 mm |
3,50 |
² |
² |
¹ 0 |
|
|
62,5 cm (50%) Boiler slag (750 kg/m³) |
10,00 |
0,330 |
0,30 |
4 |
|
|
62,5 cm (12%) Timber (475 kg/m³ - e.g. spruce/fir) - rough, air-dried |
2,50 |
0,120 |
0,21 |
-1 |
|
|
16 cm (20%) Timber (475 kg/m³ - e.g. spruce/fir) - rough, air-dried |
16,00 |
0,120 |
1,33 |
-1 |
|
|
Rsi / Rse = |
0,170 / 0,170 |
|
|
|
R' / R'' (max. relative error: 3,0%) = |
1,175 / 1,107 |
|
|
|
building element |
21,53 |
|
1,141 |
2 |
|