Synthesa Capatect Hanf Wall Fassadendämmplatte
link to this page:
https://www.baubook.at/m/PHP/Info.php?SI=2142722541&SW=16&lng=2

Manufacturer
Synthesa Chemie GesmbH
A-4320 Perg
Austria
 
Description
Product groups: Hemp insulation materials
Area of application (insulating materials):
Aufzählungspunkt Composite thermal insulation system
Product photos:
Renewable raw materials: 86w%
Mineral raw materials: 1w%
Fossil raw materials: 13w%
Recycling materials: 0w%
Bitumen: 0w%
Reference value: Hemp fibre insulation boards for ETICS
 
Criteria for certification, tendering and subsidies
List of Criteria 2020
applicationcriteria
AB
2. 1. 4. Limit for plastic content in insulating materials and foils made of paper
2. 2. 2. Limits for CMR substances in insulation materials
2. 2. 12. Ban of acutely toxic substances
2. 4. 7. Additional criterion: Complete exclusion of organohalogen substances
5. 1. 6. Limits for VOC and SVOC emissions from insulating materials
A: Insulation materials with indoor air relevance
Insulation materials installed on the room side of the airtightness layer of the building.
B: Insulation materials without indoor air relevance
Insulation materials that are not installed on the room side of the building's airtightness layer.

The criteria is relevant and the product supports the fulfillment of the criterion.
The criteria is relevant and the product does not support the fulfillment of the criterion or there are no validation documents available.
The criteria is not relevant for the application.
if an application is displayed in green, all relevant criteria of this application are met.
If at least one of the relevant criteria for an application is not met, the application is displayed in red.
 
Technical characteristics
Dimensions
Format l x w: 800 mm x 600 mm
thickness: 2 cm
3 cm
4 cm
5 cm
6 cm
8 cm
10 cm
12 cm
14 cm
16 cm
18 cm
20 cm
22 cm
24 cm
 
Physical parameters
Serviceability
 
Processing properties
Installation (description): not specified
 
Life Cycle Assessment (LCA)
Background database Ecoinvent A1
A1-A3 Product stage
EI disposal indicator
reference Unit
Core environmental impact indicators
GWP-fossil Global warming potential - fossil 0,633 kg CO2 Äq./kg
GWP-biogenic Global warming potential - biogenic -1,33 kg CO2 Äq./kg
GWP-total Global warming potential - total -0,701 kg CO2 Äq./kg
ODP Depletion potential of the stratospheric ozone layer 2,56·10-8 kg CFC-11 eq./kg
AP Acidification potential 0,00286 kg SO2 Äq./kg
EP Eutrophication potential 0,000797 kg PO43- eq./kg
POCP Photochemical Ozone Creation Potential 0,000668 kg C2H4 eq./kg
Indicators describing resource use
PERE Primary energy renewable - energy resources 0,256 MJ/kg
PERM Primary energy renewable - material 13,9 MJ/kg
PERT Primary energy renewable - total 14,2 MJ/kg
PENRE Primary energy non-renewable - energy resources 10,2 MJ/kg
PENRM Primary energy non-renewable - material 2,27 MJ/kg
PENRT Primary energy non-renewable - total 12,5 MJ/kg
Quelle: IBO benchmarks 2020, ab 17.2.2023
 
 
Ecological characteristics
Ingredients
Halogen-organic compounds: not specifiedw%
 
Production of raw materials
 
Service area
CE marking
CE marking: yes
CE Declaration of Performance:
 
Ecolabels
Austrian Ecolabel
valid until April 2027
 
Download
Technical data sheet:
issued on May 30, 2023
Safety data sheet: not available
European Technical Assessment (ETA):
available
issued on Feb 14, 2020
issued by: OIB
 
Retailer
Tschabrun Hermann GmbH
A-6830 Rankweil
Austria
 
baubook declaration
Listed since: Feb 21, 2018
Amended: July 10, 2023
baubook product index: 1383 ip
 
baubook green procurement
Harmonised “EcoBuildingCriteria” provided by “ÖkoKauf Wien” and “service package sustainable construction in Vorarlberg”