show building element details
cross section of element:

| no. |
type |
layer |
d cm |
| 1 |
  |
Clay Roof Tiles1 |
3,00 |
| 2 |
  |
Battens |
3,00 |
| |
|
56,5 cm (90,4%) Vertical air layer, horizontal heat flow 25 < d = 30 mm |
3,00 |
| |
|
6 cm (9,6%) Cross laminated timber (475 kg/m³) |
3,00 |
| 3 |
  |
MDF-Board2 |
1,60 |
| 4 |
  |
HOIZ - Planed Chip Insulation, Insulation between rafters |
24,00 |
| |
|
56,5 cm (90,4%) Baufritz HOIZ S - Hobelspandämmung |
24,00 |
| |
|
6 cm (9,6%) Cross laminated timber (475 kg/m³) |
24,00 |
| 5 |
  |
vapour retarder3 |
0,01 |
| 6 |
  |
Plasterboard with Screen Level4 |
1,25 |
| 7 |
  |
Rear Ventilation, Battens |
3,00 |
| |
|
59,5 cm (95,2%) Vertical air layer, horizontal heat flow 25 < d = 30 mm |
3,00 |
| |
|
3 cm (4,8%) Cross laminated timber (475 kg/m³) |
3,00 |
| 8 |
  |
gypsum plasterboard4 |
1,25 |
| 9 |
  |
Gypsum Filler5 |
0,20 |
| additional materials (not relevant for the U-value): (quantity per m² building element) | | 0 | Baufritz-Mineralfarbe |
| |
|
building element |
37,31 |
1 Verwendeter Richtwert: Clay roof tiles (2000 kg/m³)
2 Verwendetes Produkt: AGEPAN® DWD protect
3 Verwendeter Richtwert: Polyethylene (PE) vapour brake
4 Verwendeter Richtwert: Gypsum plasterboard (700 kg/m³)
5 Verwendeter Richtwert: Filler - gypsum filler |