Last changed: baubook reference value: 13. 3. 2013 Building physics parameters: 15. 9. 2008 Ecological building parameters, IBO benchmarks 2012: 19. 2. 2020 Ecological building parameters, IBO benchmarks 2020: 19. 2. 2020 Bauprodukte Dichtungsbahnen, Dampfsperren, Folien & Vliese • Bitumenbahnen |
Kennwert | Richtw. | Einheit |
ρ | ||
Richtwert | 1.100 | |
obere Grenze | 1.100 | |
λ | ||
Richtwert | 0,230 | |
μ | ||
Richtwert | 36000 | |
c | 1260 |
EI disposal indicator | IBO 2012 | IBO 2020 | Unit |
---|---|---|---|
Core environmental impact indicators | |||
GWP-fossil Global warming potential - fossil | 0,500 | 0,502 | kg CO2 Äq./kg |
GWP-biogenic Global warming potential - biogenic | -0,314 | -0,314 | kg CO2 Äq./kg |
GWP-total Global warming potential - total | 0,185 | 0,188 | kg CO2 Äq./kg |
ODP Depletion potential of the stratospheric ozone layer | 0,000000378 | 0,000000378 | kg CFC-11 eq./kg |
AP Acidification potential | 0,00547 | 0,00547 | kg SO2 Äq./kg |
EP Eutrophication potential | 0,00109 | 0,00109 | kg PO43- eq./kg |
POCP Photochemical Ozone Creation Potential | 0,000308 | 0,000756 | kg C2H4 eq./kg |
Indicators describing resource use | |||
PERE Primary energy renewable - energy resources | 4,30 | 4,30 | MJ/kg |
PERM Primary energy renewable - material | 2,47 | 2,47 | MJ/kg |
PERT Primary energy renewable - total | 6,77 | 6,77 | MJ/kg |
PENRE Primary energy non-renewable - energy resources | 7,73 | 7,73 | MJ/kg |
PENRM Primary energy non-renewable - material | 35,1 | 35,1 | MJ/kg |
PENRT Primary energy non-renewable - total | 42,9 | 42,9 | MJ/kg |
|