MEALUXIT Zarge mit Fensterrahmen Dreh-Kipp
link to this page:
https://www.baubook.at/m/PHP/Info.php?SI=2142693521&SW=16&lng=2

Manufacturer
MEA Bausysteme GmbH (A)
A-3130 Herzogenburg
Austria
 
Description
Product groups: Plastic frame
Product photos:
 
Criteria for certification, tendering and subsidies
List of Criteria 2026 beta
List of Criteria 2020

The criteria is relevant and the product does not support the fulfillment of the criterion or there are no validation documents available.
 
Technical characteristics
Dimensions
Frame width:
oben/seitlich not specified
unten not specified
gemittelt 0,159
m
Glazing bar width:
0,03
mRichtwert
 
Physical parameters
UfHeat transmission coefficient of window frames:
oben/seitlich not specified
unten not specified
gemittelt 1,2
W/(m²·K)
 
raw materials and input materials
Ingredients
 
Life Cycle Assessment (LCA)
Reference value
Life Cycle Assessment data according to EN 15804+A1 ecoinvent (Austrian-compliant)
A1-A3 Product stage
indicator
reference Unit
Core environmental impact indicators
GWP-fossil Global warming potential - fossil 270 kg CO2 Äq./m²
GWP-biogenic Global warming potential - biogenic 0,00 kg CO2 Äq./m²
GWP-total Global warming potential - total 270 kg CO2 Äq./m²
ODP Depletion potential of the stratospheric ozone layer 1,41·10-5 kg CFC-11 eq./m²
AP Acidification potential 1,04 kg SO2 Äq./m²
EP Eutrophication potential 0,509 kg PO43- eq./m²
POCP Photochemical Ozone Creation Potential 0,178 kg C2H4 eq./m²
Indicators describing resource use
PERE Primary energy renewable - energy resources 258 MJ/m²
PERM Primary energy renewable - material 0,00 MJ/m²
PERT Primary energy renewable - total 258 MJ/m²
PENRE Primary energy non-renewable - energy resources 4.425 MJ/m²
PENRM Primary energy non-renewable - material 864 MJ/m²
PENRT Primary energy non-renewable - total 5.289 MJ/m²
Quelle: IBO reference values 2020, ab 17.2.2023
 
 
Service area
CE marking
CE marking: not specified
 
Download
Technical data sheet:
Test certificate in accordance with ÖNORM EN ISO 10077:
available
issued on Jan 11, 2007
issued by: ift Rosenheim
 
Retailer
August Rädler GmbH
A-6922 Wolfurt und Dornbirn
Austria
 
baubook declaration
declared since: Feb 2, 2007
Amended: Nov 11, 2024
baubook product index: 8610 ab
version history: öffnen
 
EcoBuildingCriteria
Harmonised “EcoBuildingCriteria” provided by “ÖkoKauf Wien” and “service package sustainable construction in Vorarlberg”
print page
share this page