| Product groups: | Primers, primer coats, moisture barriers, casting resin | ||
| Area of application (Primers, primer coats, moisture barriers, casting resin): | Moisture barriers | ||
| Product photos: | |||
![]() |
The criteria is relevant and the product supports the fulfillment of the criterion. |
| λ thermal conductivity: | 0,9 | W/(m·K) | Richtwert |
| ρ density: | 1200 | kg/m³ | Richtwert |
| c specific heat capacity: | not specified | J/(kg·K) | |
| μ Vapour diffusion resistance factor: | 1200 |
| pH value: | ranging from 6 up to 7 |
| Installation (description): | not specified | ||
| Consumption per procedure (kg/m²): | 1,2 | kg/m² | |
| Number of procedures required: | 2 | ||
| Materials used: | Teil A: Fertigmörtel (Portlandzement); Teil B: Wässrige Dispersion synthetischer Polymere | ||
| SVHC (Substances of Very High Concern): | The final product ready for sale does not contain any substance of very high concern (SVHC) of the candidate list | ||
| Halogen-organic compounds: | not specified | w% | |
| VOC (g/l): | not specified | g/l | |
| Reference value: | Adhesive - artificial resin | ||
| A1-A3 Product stage indicator |
reference | Unit |
| Core environmental impact indicators | ||
| GWP-fossil Global warming potential - fossil | 1,09 | kg CO2 Äq./kg |
| GWP-biogenic Global warming potential - biogenic | -0,00500 | kg CO2 Äq./kg |
| GWP-total Global warming potential - total | 1,08 | kg CO2 Äq./kg |
| ODP Depletion potential of the stratospheric ozone layer | 9,72·10-8 | kg CFC-11 eq./kg |
| AP Acidification potential | 0,00414 | kg SO2 Äq./kg |
| EP Eutrophication potential | 0,00155 | kg PO43- eq./kg |
| POCP Photochemical Ozone Creation Potential | 0,000896 | kg C2H4 eq./kg |
| Indicators describing resource use | ||
| PERE Primary energy renewable - energy resources | 0,607 | MJ/kg |
| PERM Primary energy renewable - material | 0,00 | MJ/kg |
| PERT Primary energy renewable - total | 0,607 | MJ/kg |
| PENRE Primary energy non-renewable - energy resources | 18,6 | MJ/kg |
| PENRM Primary energy non-renewable - material | 8,33 | MJ/kg |
| PENRT Primary energy non-renewable - total | 26,9 | MJ/kg |
| CE marking: | not specified | ||
| CE Declaration of Performance: | LE_EN_14891_Mapelastic_Turbo.pdf (249 KB) issued on Sept 3, 2014 | ||
![]() PDF (285 KB) issued on Jan 18, 2022 valid until January 2027 |
| H phrases: | H330, H315, H318, H411, H317, H400, H302, H314, H317, H410, H301, H311, H331 | ||
| GISCODE for floor-laying materials: | No GISCODE applicable | ||
| Technical data sheet: | issued on July 1, 2015 | ||
| Safety data sheet: |
| ||
| Other environmental product declarations (non-compliant): | valid until Sept 25, 2027 | ||
| Other forms of proof: | DOP EN 1504-2 (163 KB) | ||
| declared since: | May 29, 2017 | ||
| Amended: | Aug 13, 2024 | ||
| baubook product index: | 3041 cs | ||
| version history: | öffnen | ||
|